datasheet,schematic,electronic components, service manual,repairs,tv,monitor,service menu,pcb design
Schematics 4 Free
Service manuals, schematics, documentation, programs, electronics, hobby ....


registersend pass
Bulgarian - schematics repairs service manuals SearchBrowseUploadWanted

Now downloading free:Keithley 2801 Mesatronic

Keithley 2801 Mesatronic free download

Various electronics service manuals

File information:
File name:2801 Mesatronic.pdf
[preview 2801 Mesatronic]
Size:144 kB
Extension:pdf
Mfg:Keithley
Model:2801 Mesatronic 🔎
Original:2801 Mesatronic 🔎
Descr: Keithley Appnotes 2801 Mesatronic.pdf
Group:Electronics > Other
Uploaded:07-03-2020
User:Anonymous
Multipart:No multipart

Information about the files in archive:
Decompress result:OK
Extracted files:1
File name 2801 Mesatronic.pdf

WHITE PA P E R Advanced Membrane Substrate and Interconnects Will Allow Simultaneous RF and DC Measurements During Wafer Probing Background Traditionally, probe cards for parametric testers have been designed for either RF signals or low level DC measurements, but not both. This was fine as long as a semiconductor wafer contained only RF test circuits, or those designed for DC operation. However, as digital switching speeds have increased to RF frequencies, and mixed RF and DC test devices are designed into wafers, separate RF and DC probing has become very costly. It requires a changeover from one type of probe card to the other, recalibration of the parametric tester and its interconnects, and then re-probing the wafer for a second set of measurements. In addition, on-wafer testing of semiconductor devices often utilizes the interfacing between test instruments and the test points and structures located within wafer scribe lanes. As semiconductor dies and scribe lanes decrease in size, it becomes more difficult to connect test instruments to the device under test (DUT). This problem is compounded when both RF and ultra-low current DC measurements are desired. In RF measurements, an important consideration is minimizing RF signal losses through a variety of techniques, such as maintaining the desired characteristic impedance to minimize RF energy reflections along the signal path. In ultra-low current measurements (for Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com A G r e A t e r M e A s u r e o f C o n f i d e n C e example, sub-nanoamp magnitudes), it is important to minimize the effects of extraneous voltage potentials in the vicinity of the test point. To help alleviate this situation, some probe cards have recently been designed for a few RF connections, with the remaining probes calibrated for DC. This helps to some extent but limits the effectiveness of parametric test systems, most of which could be programmed to conduct either RF or DC measurements on any pin. Still, parametric testers themselves need to be designed so that interconnections on any signal path can handle either type of signal. Up to now, this type of system

>> View document online <<



>> Download document << eServiceInfo Context Help



Was this file useful ? Share Your thoughts with the other users.

User ratings and reviews for this file:

DateUserRatingComment

Average rating for this file: 0.00 ( from 0 votes)


Similar Service Manuals :
Keithley 98932C(KPCMCIA_RS422_485S) - Keithley 6514RevA_DocSpec - Keithley Selector LowV-LowR - Keithley 2765 Thermistors - Keithley 052207 4ACS - Keithley 79480C(DASCard) - Keithley 3321RevB DocSpec -
 FB -  Links -  Info / Contacts -  Forum -   Last SM download : Fisher RS1052L

script execution: 0.03 s